Gaia
GAIA.ASU.SP.ESM.00007
Issue 2.00
Page 19 of 79
Astrium Ltd owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in
whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
GAIA.ASU.SP.ESM.00007 (Avionics SCOE Req Iss 2).doc
AVI-4021/CREATED/T,R
For both Type 1 and Type 2 Power Simulation, the LCL outputs shall be fed from a common Power
Source (or multiple sources feeding LCL groups).
Note: The common Power Source is equivalent to the PCDU Main Bus regulation point.
AVI-4022/CREATED/T
The common Power Source (or sources) shall meet the following specification:
Reqt
-1 Output Voltage 28.0V ± 0.14V (±0.5%)
-2 Current Limit +10% As defined in Table 3.6-1 for all or groups
of LCL
-3 Over Voltage Protection Level 34.0V ±50mV
-4 Over Current Protection Level +200mA ±50mA of overall Current Limit
-5 Protection Response Time >5ms < 15ms (from protection occurrence)
-6 Output Ripple <100mV
AVI-4054/CREATED/T
The output impedance of any single (simulated) LCL output shall be < 20m
Ω
, including the
contribution of the cable connecting to the Spacecraft harness.
AVI-4055/CREATED/A,R
For Type 1 and Type 2 simulations, the Voltage Regulation point shall be the common Power Source.
AVI-2583/CREATED/T
In open-loop test modes, it shall be possible to switch ON/OFF LCL outputs by any of the following
methods:
• in response to commands received by the PCDU Remote Terminal of the 1553 BUS, as
defined in Section 3.6.2.2.
• by detection of the relevant SHP command , as defined in Section 3.6.9.
• by command from the local MMI.
• remotely from the CCS (Test Procedure).
AVI-4097/CREATED/T
Switch ON or OFF of LCL circuits by response to PCDU RT 1553 BUS commands and by SHP shall
both be possible, depending on Gaia command distribution requirements.
AVI-4098/CREATED/T
Switch ON or OFF of LCL circuits by local MMI and remote CCS shall be available to override
Spacecraft commanding for failure injection.
AVI-2584/CREATED/T
In closed-loop test mode, ON/OFF switching of the LCL circuits shall be achieved under the control of
the RTS, in response to MIL-STD-1553B BUS or SHP commands received by the PCDU Model.
AVI-3439/CREATED/T
The protection status of each LCL output shall be made available to the operator (local MMI).
Specifically, an error shall be raised if any protection circuit is triggered.
AVI-2750/CREATED/T
It shall be possible to switch off all LCL output by single command from the local MMI or remotely
from the CCS (Test Procedure).